Reconstruction/Rehabilitation of the listed TIETZ into "Cultural Shopping Center Chemnitz" DAStietz
with Natural History Museum, City Library, Adult Education Center, New Saxon Gallery with workshop area, Archive area, Magazines, Administration, Commerce/Gastronomy and Event areas
STRUCTURAL ENGINEERING
- sophisticated static proof of the listed existing building (reinforced concrete skeleton construction of the year 1913 with approximately 30.000 m² gross external area) for a added ceiling force of an additional 1,5 kN/m² in almost all areas
- Proof of the transverse force load-carrying capacity of all cross girders due to the available lateral ties, the building was reinforced with punt iron, a special kind of reinforcement from USA where according to the today´s regulations is no effective transverse force reinforcement is present, but only insufficiently embodied bending upward
- Control and professional monitoring of ceiling pressure tests including the interpretation for the reduction of the rehabilitation complexity
- Development of a concept for the production of a sufficient shear bearing capacity through shot concrete rehabilitation
- Increase of the floor bearing capacity through dowel jointing blinding concrete (in areas)
- Production of the area stability of the entire building through execution of the installation shafts as braced cores, the solid appearing outer walls are only non-bearing façade
- Development of special measures for temporary construction security in the break off area
CERTIFICATES
The C&E Consulting and Engineering GmbH Chemnitz is certified according to DIN EN ISO 9001:2015.
DETAILS
Services:
Overall planning and Supervision of construction,
Service phase. 1 to 9
Client:
Projektierungs- und Verwaltungs-
gesellschaft TIETZ Chemnitz mbH
Costs:
27.700 T€